Triangle Tube 111K BTU 95% AFUE Gas Boiler & Hot Water Heater Boiler

Model: CC 125H Item Number: 79458
Triangle Tube CC 125H
PREVIOUS
NEXT
Triangle Tube CC 125H
Triangle Tube CC 125H
Triangle Tube CC 125H
Triangle Tube CC 125H
Enlarge Image
Triangle Tube CC 125H
Triangle Tube CC 125H
Triangle Tube CC 125H
Triangle Tube CC 125H
View All
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    80 Pounds Learn More
    80 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Line
    Challenger Combi
    Medium
    Hot Water
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Triangle Tube CC 125H

Triangle Tube is best known for two things: feats of hydronic innovation and incredibly efficient products. The Challenger Combi Boiler brings tankless water heating to the compact, high-efficiency Challenger series of boilers. Triangle Tube retained the low NOx, low noise design of the original Challenger and added on board domestic hot water production for even greater value. The condensing technology behind Challenger Combi boilers will capture and reuse gaseous heat that escapes traditional boilers. A unique cast-aluminum heat exchanger with copper waterways provides efficient heating and exceptional durability. Vertical flueways mean that you'll enjoy those benefits in a compact design. The ease-of-installation means that there is more reason than ever to add a high-efficiency Challenger Combi boiler to your system.
  • Intelligent DHW Control
  • In ECO mode, the Challenger Combi will learn what times of day have the highest hot water demands. It will then maintain a minimum heat exchanger temperature at those times for instantaneous hot water even at high volume times.
  • Outdoor Reset Control
  • All Challenger Combi boilers include an outdoor reset sensor and outdoor reset control. This allows your boiler to regulate the temperature of your home based on the temperature outdoors which saves energy without sacrificing comfort.
  • Precision Through Sensors
  • Along with its outdoor sensor, sensors at the Challenger's supply and return measure temperature and relay that information to your boiler so it can further refine its output and guarantee comfort and efficiency.
  • Modulating Burner
  • The Challenger can make fine adjustments to heating output because of its modulating burner. This burner allows minute, incremental changes in heat production with a 4:1 turndown ratio to guarantee that you aren't using more energy than you need to be.
  • Dual Purpose Waterways
  • With a Challenger Combi, your domestic hot water is heated directly in the waterways of the heat exchanger. This eliminates the need for a secondary heat exchanger and additional equipment that is typical in other combination boilers.
  • Venting Options
  • The CC 125H vents conveniently through your wall with PVC, CPVC, PP, and SS material options. These boilers support concentric venting, which reduces the number of vent pipes from two to one, and further reduces the space necessary for installation.
  • Product Includes
  • (1) Triangle Tube CC 125H Hot Water Combi Boiler
  • (1) Outdoor Reset Sensor
  • (1) Wall Mounting Bracket
  • (1) NG to LP Gas Conversion Kit
  • Specifications
    View More

    Specifications

    General Information
    Product Line
    Challenger Combi
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Condensing
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    Yes
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Modulating
    Connection Type
    NPT
    Mount Type
    Wall
    Includes Pump
    Yes
    Assembly Type
    Packaged
    Gas Conversion Kit
    Included
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    95 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    125000 BTU
    Minimum Input Capacity
    20000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    111000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    97000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    Yes
    Electrical Data
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    3 Inches
    Cold Water Inlet
    3/4 Inch
    Hot Water Outlet
    3/4 Inch
    Supply Connection
    1 Inch
    Return Connection
    1 Inch
    Product Height
    28 Inches
    Product Width
    17 3/4 Inches
    Product Depth
    9 1/2 Inches
    Product Weight
    80 Pounds
    Shipping Weight
    90 Pounds
    Certifications
    CSA Listed
    Yes
    Energy Star Listed
    Yes
    ASME Certified
    Yes
    AHRI Certified
    Yes
    ISO Certified
    Yes
    AHRI Reference Number
    9990274
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    10 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Triangle Tube 111K BTU 95% AFUE Gas Boiler & Hot Water Heater Boiler
    Triangle Tube CC 125H
    Loading
    Triangle Tube CC 125H
    Triangle Tube CC 125H
    Triangle Tube CC 125H
    Triangle Tube CC 125H
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top