Goodman - 1.5 Ton Cooling - 30k BTU/Hr Heating - Air Conditioner + 2 Stage Furnace Kit - 14.5 SEER - 96% AFUE - For Upflow Installation
Model: GSX1418GMEC96030AUItem Number: 90231
Ask a Question
Enlarge Image
View All
Specification Highlights
Condition
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
278 Pounds 278 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
(1) Goodman 1.5 Ton 14 SEER Air Conditioner Condenser w/ R410A Refrigerant (GSX140181)
(1) Goodman 1.5 Tons 14 in. Wide Air Conditioner Cased Coil (CAPFA1818A6)
View Full Bundle
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features & Bundle Details
Features & Bundle Details
Overview for Goodman GSX1418GMEC96030AU
A Goodman central air and furnace kit is the perfect way to update your home's HVAC system. This kit contains a GSX14 air conditioner, a GMEC96 furnace, and a cased CAPFA evaporator coil making it the ideal solution for most parts of the country. It's the perfect kit for areas that use an average amount of cooling but want a multi-speed furnace for the long cold winters. Each of these components is designed with a focus on ease-of-installation and durability to provide you with upfront and long-term value. If you're looking for a complete comfort solution backed by superior craftsmanship, the Goodman GSX140181 GMEC960303AN CAPFA1818A6 air conditioner and furnace kit fits the bill perfectly.
The manufacturer model number(s): Goodman GSX140181 GMEC960303AN CAPF3636A6
AHRI Reference Number: 10515972 * *May change based on the Manufacturer revision
Product Note
The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab. | The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help.
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor
ECM Multi-Speed
Coil Width
14 Inches
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA, TX and UT)
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
1.5 Tons
Cooling Capacity
18000 BTU
Nominal Cooling Capacity
18000 BTU
Heating BTU
30000
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
14.5
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
12.5
Maximum Air Flow
650 CFM
Dimensions
Product Weight
278 Pounds
Shipping Weight
292 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
206576514
General Information
Type
Gas Furnace
Product Line
GMEC96
Product Category
Furnace
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor
ECM Multi-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Heating BTU
30000
High Fire Input
30000 BTU
High Fire Output
28800 BTU
Low Fire Input
21000 BTU
Low Fire Output
20160 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
14 Inches
Product Height
34 1/2 Inches
Product Width
14 Inches
Product Depth
28 3/4 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
10515331
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Heat Exchanger Warranty
20 Years
Overview
Product Category
Furnace
General Information
Type
Condenser
Product Line
GSX14
Product Category
Air Conditioning Condensers
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
North and Southeast
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
1.5 Tons
Cooling BTU
18000
Cooling Capacity
18000 BTU
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
14.0
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system.
12.0
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
73 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9 Amps
Recommended Breaker Size
15 Amps
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
27 1/2 Inches
Product Width
26 Inches
Product Depth
26 Inches
Product Weight
126 Pounds
Shipping Weight
141 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab.
Limited* 10 Years Years
Overview
Product Category
Air Conditioning Condensers
General Information
Type
Evaporator Coil
Product Line
CAPF
Product Category
Evaporator Coil
Refrigerant Type
R-22/R-410A
Casing
Cased
Style
A Coil
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
1.5 Tons
Cooling BTU
18000
Nominal Minimum Cooling Capacity
18000 BTU
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
14 Inches
Product Height
18 Inches
Product Width
14 Inches
Product Depth
21 Inches
Product Weight
23 Pounds
Shipping Weight
33 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab.
10 Years
Overview
Product Category
Evaporator Coil
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Goodman - 1.5 Ton Cooling - 30k BTU/Hr Heating - Air Conditioner + 2 Stage Furnace Kit - 14.5 SEER - 96% AFUE - For Upflow Installation