Williams Forsaire - 40k BTU - Gas Direct-Vent Wall Furnace - 75.4% AFUE - Standing Pilot

Model: 4007732 Item Number: 71203
Williams 4007732
PREVIOUS
NEXT
Williams 4007732
Williams 4007732
Enlarge Image
Williams 4007732
Williams 4007732
View All
Originally $1,745.00, you save 5%
Our Price: $1,657.75
synchrony card icon
$277 / Month
Suggested monthly payments with 6 month financing.
In-Stock
Ships Wednesday, December 4th
Shipping to60601
Williams Forsaire - 40k BTU - Gas Direct-Vent Wall Furnace - 75.4% AFUE - Standing Pilot
Williams Forsaire - 40k BTU - Gas Direct-Vent Wall Furnace - 75.4% AFUE - Standing Pilot Model: 4007732 Item Number: 71203
$1,657.75
In-Stock
-
+
Accessories
Features
Specifications
Reviews
Product Q&A
Manuals
Shipping Crate Icon
Free Shipping Learn More
Free Shipping
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges map apply, see our full shipping policy for more details.
Truck Icon
Free Lift Gate Learn More
Free Lift Gate
*This product qualifies for Free Lift Gate Service. Items over 100lbs normally ship via semi-truck. Select this service if you need the product lowered to the ground curbside. To learn more about Lift Gate Service, read our shipping policy.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    116 Pounds Learn More
    116 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Category
    Furnace
    UPC
    093909298906
Heating Capacity (BTU/Hr)
Select Attribute
Vent Type
Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Select Attribute
Fuel Type
Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Select Attribute
Pilot Type
Select Attribute
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Williams 4007732

Safety is no worry with this furnace, having a matchless pilot igniter and sealed combustion chamber requiring no inside air. Whether recessed into the wall or surface mounted, the soft-white powder coated finish provides a discrete durable finish that blends into any home's decor.
  • Sealed Combustion
  • Rather than using indoor air to fuel combustion, the Williams direct vent pulls intake air directly from the outdoors. This means the heat your furnace generates isn't fed back into the system, maximizing efficiency.
  • Counterflow Blower System
  • The Forsaire furnace has a counterflow blower system that takes air from the ceiling and blows the warm air at the floor. This allows for the heat to be evenly distributed throughout the room.
  • Safe Pilot Ignition
  • With matchless pilot ignition, the guess work is taken out of lighting the furnace. By sealing the pilot and igniter away from dirt and debris, the electronic igniter lights the furnace safely and reliably.
  • Vent Limit Safety Switch
  • The vent limit safety switch is equipped on all Forsaire furnaces. This turns off the unit in case the vent is blocked, protecting your family from carbon monoxide and fires.
  • Product Includes
  • All Vent Materials Needed for a 9" Thick Wall
  • Product Note
    A thermostat does not come included with this unit and is required. The Williams P322016 thermostat is compatible and can be found under the "Accessories" tab. Alternatively, any standard millivolt thermostat can be used.
    Specifications
    View More

    Specifications

    Overview
    Product Category
    Furnace
    UPC
    093909298906
    General Information
    Type
    Gas Wall Furnace
    Product Line
    Forsaire
    Product Category
    Furnace
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Blower Motor Type
    Single Speed
    Mount Type
    Wall
    Gas Conversion Kit
    Available
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    75.4 %
    Heating BTU
    40000
    High Fire Input
    40000 BTU
    High Fire Output
    32000 BTU
    Maximum Air Flow
    325 CFM
    Electrical Data
    Minimum Circuit Ampacity
    2 Amps
    Dimensions
    Gas Connection Size
    1/2 Inch
    Product Height
    77 3/8 Inches
    Product Width
    14 1/8 Inches
    Product Depth
    11 3/4 Inches
    Product Weight
    116 Pounds
    Shipping Weight
    126 Pounds
    Certifications
    CSA Listed
    Yes
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    10 Years
    Reviews
    5.0 out of 5 stars5.0 out of 5 stars
    (1)
    View More

    Reviews

    Product Q&A
    View More

    Product Q&A

    Be the first to ask a question.

    Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience so you can have confidence knowing that you'll be getting an insightful response.

    Manuals
    View More
     
    Share
    ×
    Williams Forsaire - 40k BTU - Gas Direct-Vent Wall Furnace - 75.4% AFUE - Standing Pilot
    Williams 4007732
    Loading
    Williams 4007732
    Williams 4007732
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top