Rinnai - 112K BTU - 95.5% AFUE - Hot Water Gas Boiler - Direct Vent
Model: I120SNItem Number: 105106
Ask a Question
Enlarge Image
View All
Specification Highlights
Condition
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
62 Pounds 62 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Line
I Series
Medium
Hot Water
View More
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Rinnai I120SN
With proven technology and reliability, the Rinnai I-Series is designed with homeowners in mind. With its exclusive self-cleaning stainless-steel heat exchanger with a secondary flat plate heat exchanger, the I-Series delivers whole house heating to increase your comfort. Fueled by either propane or natural gas, the I-Series has one of the highest AFUE ratings in the industry. The compact wall-mounted design of the I-Series allows for easy installation and saves your valuable space.
Specifications
Specifications
General Information
Product Line
I Series
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Modulating
Connection Type
NPT
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
95.5 %
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
120000 BTU
Minimum Input Capacity
15000 BTU
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
112000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
97000 BTU
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
Yes
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Turndown Ratio
8:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
2 Inches
Gas Connection Size
3/4 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
26 19/48 Inches
Product Width
18 1/2 Inches
Product Depth
10 43/48 Inches
Product Weight
62 Pounds
Certifications
Energy Star Listed
Yes
CSA Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
203306037
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Rinnai - 112K BTU - 95.5% AFUE - Hot Water Gas Boiler - Direct Vent