Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    85 Pounds Learn More
    85 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Gas Furnace
    Product Line
    WeatherKing
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Rheem W801SA050314MSA

WeatherKing provides high-quality HVAC systems that will assist you in taking control of your home comfort. Your castles inhabitants deserve reliable and efficient heat, and WeatherKing has just the right products to keep everyone comfortable. With WeatherKings efficient selection of residential Furnaces at your fingertips, you can keep discomfort out of sight, and out of mind. Your home is your castle. Keep it comfortable with WeatherKing.
  • Direct Spark Ignition
  • The WeatherKing W801S features a direct spark ignition system, the same used on gas ovens and stoves. This means the furnace will only fire when it is needed, unlike a less efficient constant pilot light.
  • Quiet Operation
  • The W801S is built with a tight door seal to minimize noise. Rubber grommets on the motor mounts and a twist lock wire harness in the blower shelf cuts down on unwanted vibration noise.
  • Aluminized Steel Heat Exchanger
  • The aluminized steel heat exchanger in the W801S provides incredibly efficient heat transfer as well as maximum corrosion resistance and thermal fatigue reliability.
  • LED Display
  • An industry first, WeatherKing furnaces feature a 7-segment LED display, making service calls quick and easy.
  • Specifications
    View More

    Specifications

    General Information
    Type
    Gas Furnace
    Product Line
    WeatherKing
    Product Sub-line
    W801S
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Blower Motor Type
    PSC Multi-Speed
    Configuration Learn More
    Configuration
    Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
    Upflow/Horizontal
    Gas Conversion Kit
    Available
    UPC
    662021366949
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    80 %
    Heating BTU
    50000
    High Fire Input
    50000 BTU
    High Fire Output
    41000 BTU
    Maximum Air Flow
    1361 CFM
    Low NOx Emissions Learn More
    Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Phase
    1
    Frequency
    60 Hz
    Minimum Circuit Ampacity
    9 Amps
    Recommended Breaker Size
    15 Amps
    Dimensions
    Cabinet Width
    14 Inches
    Product Height
    34 Inches
    Product Width
    14 Inches
    Product Depth
    28 1/16 Inches
    Product Weight
    85 Pounds
    Shipping Weight
    85 Pounds
    Certifications
    AHRI Certified
    Yes
    ISO Certified
    Yes
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    5 Years
    Heat Exchanger Warranty
    10 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Rheem 80% AFUE 50,000 BTU Upflow/Horizontal Gas Furnace
    Rheem W801SA050314MSA
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top