This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
Rheem RTG - 5.5 GPM at 60° F Rise - 0.82 UEF - Propane Tankless Water Heater - Concentric Vent
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Product Category
Water Heater - Tankless
UPC
020352671345
View More
Maximum Flow Rate (GPM)
Installation Location
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Rheem Tankless RTG-95DVLP-1
Rheem has been the leader in water heating for nearly 100 years, offering savings, comfort and the protection you need. Providing continuous hot water in a compact, space savings design, Rheem tankless water heaters are the perfect solution for any sized home.
Low Flow Activation
Ideal performance even in low demand situations, the Rheem RTG has a minimum flow rate of 0.26 GPM and a minimum activation flow rate of 0.40 GPM that will ensure you will receive hot water when you need it.
EcoNet® Compatible
With the ability to be connected to the EcoNet® mobile app by using the Tankless EcoNet® Accessory Kit (sold separately) you can receive mobile alerts for notifications and maintenance reminders.
Water Savings Setting
Save up to 1,100 gallons of water a year with the Water Savings Setting on the Rheem RTG tankless water heater. Water flow is decreased through the pipes until the temperature reaches the heater's set temperature.
Specifications
Specifications
Overview
Product Category
Water Heater - Tankless
UPC
020352671345
General Information
Type
Tankless Water Heater
Product Line
Classic Plus
Product Category
Water Heater - Tankless
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Copper
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Non-Condensing
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Concentric Vent
Venting Category Venting CategoryVenting Category describes what type of flue material can be used in water heater installations. Category III: Stainless Steel, Category IV: ABS, PVC, CPVC, PolyPro, Stainless Steel
III
Storage Type
Tankless
Application
Residential
Mount Type
Wall
Installation Location
Indoor
Maximum Altitude
8400 Feet
Includes Pump
No
Gas Conversion Kit
Not Available
Performance
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
199900 BTU
Minimum Input Capacity
11000 BTU
Flow Rate at 40F Temperature Rise Flow Rate at 40F Temperature RiseFlow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location.
8.5 GPM
Flow Rate at 50F Temperature Rise Flow Rate at 50F Temperature RiseFlow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location.
6.6 GPM
Flow Rate at 60F Temperature Rise Flow Rate at 60F Temperature RiseFlow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location.
5.5 GPM
Flow Rate at 70F Temperature Rise Flow Rate at 70F Temperature RiseFlow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location.
4.7 GPM
Uniform Energy Factor Uniform Energy FactorUniform Energy Factor (UEF) is a measurement of water heater energy efficiency. The higher the energy factor, the more efficient the water heater.
0.82
Minimum Flow Rate
0.26 GPM
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Primary Vent Pipe Diameter
3 Inches
Gas Connection Size
3/4 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Product Height
25 5/8 Inches
Product Width
13 7/8 Inches
Product Depth
9 7/8 Inches
Shipping Width
12 5/8 Inches
Shipping Depth
18 1/4 Inches
Shipping Length
34 3/16 Inches
Shipping Weight
62 Pounds
Intake Diameter
3 Inches
Exhaust Diameter
5 Inches
Certifications
CSA Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
NSF Certified NSF CertifiedThe National Sanitation Foundation has developed public health standards and certification programs to protect the world's food, water, consumer products and environment.
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Rheem RTG - 5.5 GPM at 60° F Rise - 0.82 UEF - Propane Tankless Water Heater - Concentric Vent