Revolv - 3.5 Ton Cooling - 90k BTU/Hr Heating - Heat Pump + Gas Furnace System - 14.3 SEER2 - For Downflow Installation

Model: RSH3ME42MG1E-090 Item Number: 148792
Revolv RSH3ME42MG1E-090
PREVIOUS
NEXT
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
Enlarge Image
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
Revolv RSH3ME42MG1E-090
View All
Our Price: $5,239.00
synchrony card icon
$66 / Month
With our 132 months 9.99% APR*
132 fixed monthly payments required.
Only 1 In-Stock
Ships Monday, November 11th
Shipping to60601
Revolv - 3.5 Ton Cooling - 90k BTU/Hr Heating - Heat Pump + Gas Furnace System - 14.3 SEER2 - For Downflow Installation
Revolv - 3.5 Ton Cooling - 90k BTU/Hr Heating - Heat Pump + Gas Furnace System - 14.3 SEER2 - For Downflow Installation Model: RSH3ME42MG1E-090 Item Number: 148792
$5,239.00
Only 1 In-Stock
-
+
Accessories
Features
Specifications
Reviews
Product Q&A
Manuals
Shipping Crate Icon
Free Shipping Learn More
Free Shipping
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges map apply, see our full shipping policy for more details.
Truck Icon
Free Lift Gate Learn More
Free Lift Gate
*This product qualifies for Free Lift Gate Service. Items over 100lbs normally ship via semi-truck. Select this service if you need the product lowered to the ground curbside. To learn more about Lift Gate Service, read our shipping policy.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Product Category
    Furnace & Heat Pump Package
    Vent Type
    Direct Vent
    Refrigerant Type
    R-410A
Bundle Includes 3 items
  • product image
    (1) Revolv 3.5 Ton - Heat Pump - Manufactured Home - 14.3 SEER2 - Single-Stage - R-410A Refrigerant (RSH3ME4M1SP42)
  • product image
    (1) Revolv MG1E - 90k BTU - Gas Furnace - Manufactured Home - 80% AFUE - Includes Coil Cabinet (MG1E-090B)
  • product image
    (1) Revolv - 3.5 Ton - Upflow/Downflow Micro-Channel A-Coil - Uncased (C84DAMX42U-B)
Cooling Capacity (Tons)
Learn More
Cooling Capacity (Tons)
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
Select Attribute
Furnace Capacity (BTU/h)
Select Attribute
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features & Bundle Details
View More

Features & Bundle Details

Overview for Revolv RSH3ME42MG1E-090

Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. Designed for easy installation in mobile and manufactured housing, these units are specifically designed to fit into tight spaces and operate with minimum combustion clearances. A cost-efficient solution to cooling and heating your home, this kit includes a 14.3 SEER2 heat pump paired with a powerful gas furnace. With their low cost and compact design, Revolv heating and cooling systems are the perfect match for your mobile or manufactured home.
  • Corrosion Resistant Finish
  • Revolv sweat fit heat pumps are made with galvanized steel and a polyester urethane coat, creating a durable and corrosion resistant finish.
  • Composite Base Pan
  • A composite base pan is stronger and lighter than your standard steel base pan. Being composite, it absorbs sound better while remaining corrosion resistant.
  • ECM Motor
  • The MG1E includes a high efficiency ECM blower motor, granting powerful CFM ratings at the fraction of the energy costs of traditional PSC motors.
  • Economical
  • With a robust cabinet designed to fit the standard MH footprint, the MG1E is Revolv's most economical, HUD-compliant gas furnace.
  • 10 Year Limited Warranty
  • Register your system on stylecrestinc.com within 60 days of installation to extend the Parts-Only warranty coverage to 10 years.
  • Bundle Includes 3 items
    Specifications
    View More

    Specifications

    Included In This Bundle

    Bundle Overviewgrey arrow icon
    General Information
    Product Category
    Furnace & Heat Pump Package
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    Refrigerant Type
    R-410A
    Stages
    Single
    Blower Motor Type
    ECM Multi-Speed
    Connection Type
    Sweat
    Installation Location
    Outdoor
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
    Nationwide
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    80 %
    Capacity Learn More
    Capacity
    Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
    3.5 Tons
    Heating BTU
    90000
    SEER2 Learn More
    SEER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
    14.3
    EER2 Learn More
    EER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
    11.8
    Electrical Data
    Voltage
    208/230 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Suction Connection Size
    7/8 Inch
    Liquid Connection Size
    3/8 Inch
    Certifications
    ETL Listed
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    209851999
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    5 Yr Limited Years
    General Information
    Type
    Heat Pump Condenser
    Product Category
    Heat Pump
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
    Heating and Cooling
    Refrigerant Type
    R-410A
    Connection Type
    Sweat
    Installation Location
    Outdoor
    Compressor Stages Learn More
    Compressor Stages
    Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
    Single Stage
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
    Nationwide
    Performance
    Capacity Learn More
    Capacity
    Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
    3.5 Tons
    Cooling Capacity
    39000 BTU
    Heating Capacity
    41000 BTU
    Maximum Sound Level Learn More
    Maximum Sound Level
    Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
    79 dB
    SEER2 Learn More
    SEER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
    14.3
    EER2 Learn More
    EER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
    11.8
    Electrical Data
    Voltage
    208/238 Volts
    Phase
    1
    Frequency
    60 Hz
    Recommended Breaker Size
    40 Amps
    Dimensions
    Suction Connection Size
    7/8 Inch
    Liquid Connection Size
    3/8 Inch
    Product Height
    45 1/4 Inches
    Product Width
    31 3/4 Inches
    Product Depth
    31 3/4 Inches
    Shipping Weight
    201 Pounds
    Certifications
    ETL Listed
    Yes
    AHRI Certified
    Yes
    Warranty Information
    Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
    5 Years
    General Information
    Type
    Gas Furnace
    Product Line
    MG1E
    Product Category
    Furnace
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Blower Motor Type
    ECM Multi-Speed
    Configuration Learn More
    Configuration
    Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
    Downflow
    Gas Conversion Kit
    Included
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    80 %
    Heating BTU
    90000
    High Fire Input
    90000 BTU
    High Fire Output
    68000 BTU
    Maximum Air Flow
    1590 CFM
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Low NOx Emissions Learn More
    Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    120 Volts
    Phase
    1
    Frequency
    60 Hz
    Recommended Breaker Size
    15 Amps
    Dimensions
    Gas Connection Size
    1/2 Inch
    Cabinet Width
    19 7/8 Inches
    Product Height
    76 Inches
    Product Width
    19 7/8 Inches
    Product Depth
    23 3/4 Inches
    Shipping Weight
    171 Pounds
    Certifications
    AHRI Certified
    Yes
    AHRI Reference Number
    204541469
    Warranty Information
    Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
    2 Years
    Overview
    Product Category
    Furnace
    General Information
    Type
    Evaporator Coil
    Refrigerant Type
    R-410A
    Casing
    Uncased
    Style
    A Coil
    Connection Type
    Sweat
    Configuration Learn More
    Configuration
    Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
    Upflow/Downflow
    Performance
    Capacity Learn More
    Capacity
    Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
    3.5 Tons
    Cooling BTU
    42000
    Dimensions
    Suction Connection Size
    3/8 Inch
    Liquid Connection Size
    7/8 Inch
    Product Height
    18 Inches
    Product Width
    18 1/8 Inches
    Product Depth
    19 1/2 Inches
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Product Q&A
    View More

    Product Q&A

    Be the first to ask a question.

    Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience so you can have confidence knowing that you'll be getting an insightful response.

    Manuals
    View More
    Share
    ×
    Revolv - 3.5 Ton Cooling - 90k BTU/Hr Heating - Heat Pump + Gas Furnace System - 14.3 SEER2 - For Downflow Installation
    Revolv RSH3ME42MG1E-090
    Loading
    Revolv RSH3ME42MG1E-090
    Revolv RSH3ME42MG1E-090
    Revolv RSH3ME42MG1E-090
    Revolv RSH3ME42MG1E-090
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top