ProSelect® Force™ 149k 82.2% AFUE Steam Gas Boiler Chimney Vent
Model: FORCESTEAM08NHItem Number: 111062
Ask a Question
Enlarge Image
Specification Highlights
Condition
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Product Category
Boiler
View More
Net IBR Capacity (BTU/hr)
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for ProSelect Force Boilers FORCESTEAM08NH
ProSelect® Force™ boilers are high efficiency boilers available in a variety of sizes to fit your needs. The ProSelect® Force™ steam gas boiler features an electronic ignition, making it safe and reliable. The built-in draft diverter allows the boiler to be installed in lows spaces. The heavy duty ProSelect® Force™ steam gas boiler comes fully assembled with a cast iron heat exchanger. With metal section connectors that resist rust, the life of the boiler is increased.
ProSelect® Force™ Steam Gas Boiler Features Fully Assembled Electronic Ignition Built-In Draft Diverter Cast Iron Heat Exchanger Honeywell Gas Valve Metal section connectors
ProSelect® Force™ Steam Gas Boiler Features
Fully Assembled
Electronic Ignition
Built-In Draft Diverter
Cast Iron Heat Exchanger
Honeywell Gas Valve
Metal section connectors
Specifications
Specifications
Overview
Product Category
Boiler
General Information
Product Line
Force
Product Category
Boiler
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Heat Exchanger Material
Cast Iron
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Single Stage
Mount Type
Floor
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
82.2 %
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
241000 BTU
Input Rate
241 GPH
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
199000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
149000 BTU
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
7 Inches
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
40 7/16 Inches
Product Width
29 Inches
Product Depth
30 Inches
Shipping Weight
690 Pounds
Certifications
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
8330183
Warranty Information
Heat Exchanger Warranty
10 Years
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
ProSelect® Force™ 149k 82.2% AFUE Steam Gas Boiler Chimney Vent