Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
ProSelect® Force™ Boilers - 114k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent
Model: FORCE05ENRHG1Item Number: 111071
(1)
Ask a Question
Enlarge Image
Specification Highlights
Condition
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
284 Pounds 284 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Boiler
View More
DOE Heating Capacity (BTU/hr)
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for ProSelect Force Boilers FORCE05ENRHG1
ProSelect® Force™ boilers are high efficiency boilers available in a variety of sizes to fit your needs. With a design that can be piped from either side and drop-in installation for most applications, the ProSelect® Force™ hot water gas boiler is convenient to install. Featuring a Honeywell electronic ignition, the ProSelect® Force™ hot water boiler is safe and reliable.
ProSelect® Force™ Hot Water Gas Boiler Features
Can be piped from either side
Honeywell Electronic Ignition
Honeywell Gas Valve
Built-In Low Water Cut-off
Grundfos® Alpha 2™ circulator
Drop-in replacement for most installations
Limited Lifetime Warranty on Heat Exchanger
Specifications
Specifications
Overview
Product Category
Boiler
General Information
Product Line
Force
Product Category
Boiler
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Mount Type
Floor
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
84.0 %
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
136000 BTU
Input Rate
136 GPH
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
114000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
99000 BTU
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Gas Connection Size
1/24 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
40 Inches
Product Width
19 Inches
Product Weight
284 Pounds
Shipping Weight
357 Pounds
Certifications
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
202901894
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Limited Lifetime Years
Reviews
(1)
Reviews
Product Q&A
Product Q&A
Be the first to ask a question.
Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience
so you can have confidence knowing that you'll be getting an insightful response.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
ProSelect® Force™ Boilers - 114k BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent