This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
95 Pounds 95 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Boiler
UPC
817000013653
View More
DOE Heating Capacity (BTU/Hr)
Fuel Type
Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Noritz NRCB180DV-LP
Through their advancements in home comfort technology, Noritz has developed the first and only combination boiler on the market that can simultaneously provide space heating and domestic hot water for residential applications. With the Noritz NRCB Combi Gas Boiler, you can rest assured that there won't be a drop in room temperature while running hot water. The NRCB uses stainless steel primary and secondary heat exchangers, ensuring increased durability and efficiency over traditional heat exchangers. With an AFUE rating of 95%, the NRCB provides a cost-effective home comfort solution in almost any residential application.
Simultaneous Space Heating and DHW
A first of its kind, the Noritz NRCB180 provides simultaneous domestic hot water and space heating, meaning you will never have to worry about a drop in room temperature when taking a hot shower.
Corrosion Resistant Heat Exchanger
The NRCB180 features 316L stainless steel primary and secondary heat exchangers which offer higher corrosion resistance than traditional heat exchangers, increasing durability and lifespan.
Temperature Controls
The NRCB180 comes with a remote thermostat that can precisely adjust output temperatures. It also features an outdoor reset control with an included outdoor temperature sensor.
Made with Safety in Mind
Noritz boilers have built-in safety devices that protect your unit including a flame sensor, safety lock-out, high elevation adjustment, overheat prevention device, lightning protection device, and freeze protection device.
Automatic Water Feeder
All Noritz Combi boilers feature a built-in automatic water feeder that maintains pressure in your hydronic system, automatically filling up with water as required.
Product Note
When using this model for heating 160 degree output or above, CPVC or PolyPro venting is required. Concentric vent kits are not able to be used in the application. The intake can still be PVC material.
Specifications
Specifications
Overview
Product Category
Boiler
UPC
817000013653
General Information
Product Line
NRCB
Product Category
Boiler
Medium MediumMedium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Stainless Steel
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Combustion Type Combustion TypeCondensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production DHW ProductionDHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Modulating
Mount Type
Wall
Installation Location
Indoor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Gas Conversion Kit
Not Available
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
95 %
Maximum Input Capacity Maximum Input CapacityThe Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
100000 BTU
Minimum Input Capacity
18000 BTU
DOE Heating Capacity DOE Heating CapacityAlso referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
92000 BTU
Net I=B=R Capacity Net I=B=R CapacityI=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
80000 BTU
Minimum Flow Rate
0.4 GPM
Maximum Flow Rate
9.8 GPM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
Yes
Turndown Ratio
5.6
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/4 Inch
Flue Connection Size
3 Inches
Condensate Drain Size
1/2 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Boiler Supply
1 Inch
Boiler Return
1 Inch
Product Height
27 Inches
Product Width
18 1/2 Inches
Product Depth
12 19/24 Inches
Product Weight
95 Pounds
Shipping Weight
105 Pounds
Certifications
Energy Star Listed
Yes
CSA Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
10511677
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
10 Years
Reviews
(1)
(1)
Reviews
Product Q&A
Product Q&A
Be the first to ask a question.
Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience
so you can have confidence knowing that you'll be getting an insightful response.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.