This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson location near you.
Answer:
Your nearest pickup location within a 50-mile radius is automatically selected when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
Answer:
Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
Answer:
Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Make sure to check your junk/spam folder. Orders not picked up within two business days may be canceled. You should opt to have your items shipped if you cannot pick them up promptly.
Answer:
During checkout, you will be prompted to enter the name, mobile phone number, and email address of the person who will be picking up the order. For your protection, only you or your designated pickup party may pick up your order. You will need your order confirmation and a government-issued photo ID to pick up your order.
Answer:
Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Answer:
Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Answer:
Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Answer:
Make sure to have your order confirmation and a government-issued photo ID available when picking up your order. Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be needed to secure the items for transport.
Goodman - 2.0 Ton Cooling - 40k BTU/Hr Heating - Air Conditioner + Heat Pump + Furnace System - 14.5 SEER2 - 96% AFUE - Upflow
New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
355 Pounds 355 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Product Category
Furnace & Heat Pump Package
Operating Mode
Heating and Cooling
View More
Bundle Includes 3 items
(1) Goodman GSZH5 - 2.0 Ton - Heat Pump - 15.2 SEER2 - Single Stage - R-410A Refrigerant (GSZH502410)
(1) Goodman CAPTA - 2 Ton - Upflow/Downflow A Coil - Cased - TXV Included - 17.5" Width (CAPTA2422B4)
View Full Bundle
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features & Bundle Details
Features & Bundle Details
Overview for Goodman GSZH502410 GMVC960403BN CAPTA2422B4
A Goodman heat pump and furnace kit is the perfect way to update your home's HVAC system. This kit contains a GSZH5 air conditioner, a GMVC96 furnace, and a cased CAPTA evaporator coil making it the ideal solution for most parts of the country. Each of these components is designed with a focus on ease-of-installation and durability to provide you with upfront and long-term value. If you are looking for a complete comfort solution backed by superior craftsmanship, the Goodman GSZH502410 GMVC960403BN CAPTA2422B4 heat pump and furnace kit fits the bill perfectly.
All-Aluminum Coil
Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
Internal Thermostatic Expansion Valve
The CAPTA has a factory-installed internal thermostatic expansion valve. This streamlines installation and maintains ideal refrigerant flow for your system.
Secure Cabinet
A galvanized, embossed, and insulated cabinet protects this coil and prevents air leakage, providing superior longevity and efficiency.
Condensate Management
The CAPTA features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
Advanced Heat Exchanger Design
The GMVC96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
Secondary Heat Exchanger
This furnace produces additional heat by directing combustion gases through a secondary heat exchanger before they are vented. The secondary heat exchanger is made of corrosion-resistant stainless steel and it is sloped to prevent condensate build-up.
Venting Options
The GMVC960403BN offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air.
ComfortBridge™ Compatible
This furnace is compatible with Goodman's ComfortBridge™ communicating controls. ComfortBridge™ control streamlines the installation and maintenance processes by detecting the equipment and providing diagnostics and troubleshooting.
Auto-Comfort
Goodman's Auto-Comfort mode is available in applications where the GMVC960403BN is used to distribute cooled air. This mode scales output up to the cooling demand in stages for improved comfort, efficiency, and dehumidification.
Easy Integration
The GMVC960403BN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
Energy-Efficient Compressor
This unit utilizes an energy-efficient compressor to provide refrigerant flow.
Smartshift™ Technology
This unit offers a time-delay defrost that allows for a reliable, quiet and smooth transition when units enter defrost mode.
Copper Tube/Enhanced Aluminum Fin Coil
The condenser coil of this air conditioner is designed with aluminum fins and copper tubing to maximize efficiency. The fins serve to increase surface area, allowing the heat transfer capabilities of the materials to shine.
Factory-Installed Suction-Line Accumulator
An accumulator prevents compressor damage from a sudden surge of liquid refrigerant and oil that could enter the compressor from the suction line.
Factory-Installed Compressor Crankcase Heater
A crankcase heater is a supplemental electric resistance heater that prevents refrigerant migration by holding oil in the crankcase at a higher temperature than the coldest part on the system.
Factory-Installed High-Capacity Muffler
A muffler reduces noise and high-frequency vibrations that can easily be transmitted through the tubing and into the house.
High And Low-Pressure Switches
A pressure switch will suspend heat pump operations if it detects an unsafe pressure level.
Secure Cabinet
The removable grille-style top design is UL 60335-2-40 compliant.
Heavy-Gauge Galvanized-Steel Cabinet
This cabinet is built to last. Galvanized steel construction, a durable and attractive architectural gray powder-paint finish with 500-hour salt-spray approval, and a steel louver coil guard that protects your equipment from wear and tear.
Extended Warranty
Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Product Note
The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab.
Bundle Includes 3 items
Goodman GSZH5 - 2.0 Ton - Heat Pump - 15.2 SEER2 - Single Stage - R-410A Refrigerant
Model: GSZH502410
Item Number: 124476
Quantity: 1
Goodman 96% AFUE 40,000 BTU Variable Speed Upflow Gas Furnace
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Refrigerant Type
R-410A
Blower Motor Type
ECM Variable-Speed
Coil Width
17.5 Inches
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA)
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Cooling Capacity
24000 BTU
Nominal Cooling Capacity
24000 BTU
Heating BTU
40000
Maximum Air Flow
1200 CFM
SEER2 SEER2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
14.5
EER2 EER2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
12.0
HSPF2 HSPF2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
7.5
Dimensions
Product Weight
355 Pounds
Shipping Weight
385 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
208510388
General Information
Type
Heat Pump Condenser
Product Line
GSZH5
Product Category
Heat Pump
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Cooling BTU
24000
Cooling Capacity
24000 BTU
Heating Capacity
24000 BTU
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
72 dB
SEER2 SEER2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
15.2
HSPF2 HSPF2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
7.8
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15.3 Amps
Recommended Breaker Size
25 Amps
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
35 3/4 Inches
Product Width
35 1/2 Inches
Product Depth
35 1/2 Inches
Product Weight
193 Pounds
Shipping Weight
213 Pounds
Certifications
Energy Star Listed
No
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
Limited* 10 Years Years
Compressor Warranty
LIFETIME Years
General Information
Type
Gas Furnace
Product Line
GMVC96
Product Category
Furnace
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Two Stage
Blower Motor Type
ECM Variable-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide (Except CA)
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
96 %
Heating BTU
40000
High Fire Input
40000 BTU
High Fire Output
38400 BTU
Low Fire Input
28000 BTU
Low Fire Output
26880 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
114 Pounds
Shipping Weight
114 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368841
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Heat Exchanger Warranty
20 Years
Overview
Product Category
Furnace
General Information
Type
Evaporator Coil
Product Line
CAPTA
Product Category
Evaporator Coil
Refrigerant Type
R-410A
Casing
Cased
Style
A Coil
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
TXV Installed
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2 Tons
Cooling BTU
24000
Nominal Minimum Cooling Capacity
24000 BTU
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
17 1/2 Inches
Product Height
22 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
48 Pounds
Shipping Weight
58 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab.
5 Years
Overview
Product Category
Evaporator Coil
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.
Continue Shopping
×
Goodman - 2.0 Ton Cooling - 40k BTU/Hr Heating - Air Conditioner + Heat Pump + Furnace System - 14.5 SEER2 - 96% AFUE - Upflow