Goodman GSZB - 3.0 Ton - Heat Pump - 14.3 SEER2 - Single Stage - R-410A Refrigerant

Model: GSZB403610 Item Number: 138698
Goodman GSZB403610
PREVIOUS
NEXT
Goodman GSZB403610
Enlarge Image
Not For Individual Sale
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    214 Pounds Learn More
    214 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Heat Pump Condenser
    Product Line
    GSZB4
Size (Tons)
Learn More
Size (Tons)
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
Select Attribute
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Goodman GSZB403610

Goodman's GSZB4 heat pump has a nominal SEER rating of 14.3 SEER2 and a minimum HSPF2 of 7.5 to ensure efficient comfort regardless of your application. The GSZB4's design allows it to be quickly installed and serviced. It includes advanced components that protect the coil and compressor to ensure reliable operations and peace of mind. Order a GSZB4 heat pump today and enjoy efficient comfort from a single piece of equipment through all four seasons.
  • Energy-Efficient Compressor
  • This unit utilizes an energy-efficient compressor to provide refrigerant flow.
  • Smartshift™ Technology
  • This unit offers a time-delay defrost that allows for a reliable, quiet and smooth transition when units enter defrost mode.
  • Copper Tube/Enhanced Aluminum Fin Coil
  • The condenser coil of this air conditioner is designed with aluminum fins and copper tubing to maximize efficiency. The fins serve to increase surface area, allowing the heat transfer capabilities of the materials to shine.
  • Factory-Installed Suction-Line Accumulator
  • An accumulator prevents compressor damage from a sudden surge of liquid refrigerant and oil that could enter the compressor from the suction line.
  • Factory-Installed Compressor Crankcase Heater
  • A crankcase heater is a supplemental electric resistance heater that prevents refrigerant migration by holding oil in the crankcase at a higher temperature than the coldest part on the system.
  • Factory-Installed High-Capacity Muffler
  • A muffler reduces noise and high-frequency vibrations that can easily be transmitted through the tubing and into the house.
  • High And Low-Pressure Switches
  • A pressure switch will suspend heat pump operations if it detects an unsafe pressure level.
  • Secure Cabinet
  • The removable grille-style top design is UL 60335-2-40 compliant.
  • Heavy-Gauge Galvanized-Steel Cabinet
  • This cabinet is built to last. Galvanized steel construction, a durable and attractive architectural gray powder-paint finish with 500-hour salt-spray approval, and a steel louver coil guard that protects your equipment from wear and tear.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
  • Product Note
    The recommended line set size for this unit will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab.
    Specifications
    View More

    Specifications

    General Information
    Type
    Heat Pump Condenser
    Product Line
    GSZB4
    Product Category
    Heat Pump
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
    Heating and Cooling
    Refrigerant Type
    R-410A
    Installation Location
    Outdoor
    Compressor Stages Learn More
    Compressor Stages
    Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
    Single Stage
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
    Nationwide
    Performance
    Capacity Learn More
    Capacity
    Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
    3.0 Tons
    Cooling BTU
    36000
    Cooling Capacity
    36000 BTU
    Heating Capacity
    36000 BTU
    Maximum Sound Level Learn More
    Maximum Sound Level
    Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
    72 dB
    SEER2 Learn More
    SEER2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
    14.3
    HSPF2 Learn More
    HSPF2
    The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
    7.5
    Electrical Data
    Voltage
    208/230 Volts
    Phase
    1
    Frequency
    60 Hz
    Minimum Circuit Ampacity
    21 Amps
    Recommended Breaker Size
    35 Amps
    Dimensions
    Suction Connection Size
    7/8 Inch
    Liquid Connection Size
    3/8 Inch
    Product Height
    39 5/8 Inches
    Product Width
    35 1/2 Inches
    Product Depth
    35 1/2 Inches
    Product Weight
    214 Pounds
    Shipping Weight
    234 Pounds
    Certifications
    ETL Listed
    Yes
    Energy Star Listed
    No
    AHRI Certified
    Yes
    ISO Certified
    Yes
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    5 Years Years
    Compressor Warranty
    Limited* 10 Years
    Reviews
    5.0 out of 5 stars5.0 out of 5 stars
    (1)
    View More

    Reviews

    Product Q&A
    View More

    Product Q&A

    Be the first to ask a question.

    Whether it's a general or technical question ACWholesalers can help. Our customer service team is backed by years of experience so you can have confidence knowing that you'll be getting an insightful response.

    Manuals
    View More
    Share
    ×
    Goodman GSZB - 3.0 Ton - Heat Pump - 14.3 SEER2 - Single Stage - R-410A Refrigerant
    Goodman GSZB403610
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top