Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    156 Pounds Learn More
    156 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Type
    Heat Pump
    Product Line
    GSZ14
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Goodman GSZ140301-SD

***Scratch & Dent*** - Minor Fin Damage. Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GSZ14 heat pump has a nominal SEER rating of 14 and a minimum HSPF of 8.2 to ensure efficient comfort regardless of your application. The savings don't stop at energy costs; the GSZ140301's design allows it to be quickly installed and serviced. It includes advanced components that protect the coil and compressor to ensure reliable operations and peace of mind. Become a heat pump household today, and enjoy efficient comfort from a single piece of equipment through all four seasons.
Product Note
The recommended line set size for this unit will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab. | The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help. NOTE: Due to DOE regulations, as of January 1st this unit can no longer be installed in the southwest and southeast DOE regions.
Specifications
View More

Specifications

General Information
Type
Heat Pump
Product Line
GSZ14
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements.
Heating and Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Learn More
Compressor Stages
Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance Learn More
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region.
Nationwide
Performance
Capacity Learn More
Capacity
Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.5 Tons
Cooling BTU
30000
Heating Capacity
30000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system.
14.0
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB.
74 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
17.9 Amps
Recommended Breaker Size
30 Amps
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
36 1/4 Inches
Product Width
29 Inches
Product Depth
29 Inches
Product Weight
156 Pounds
Shipping Weight
172 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Show ACW Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
5 Years
Reviews
View More

Reviews

Do You Own This Product?

Give us your opinion on this product and help any future buyer's make an informed decision.

Manuals
View More
Share
×
Goodman GSZ14 - 2.5 Ton - Heat Pump - 14 Nominal SEER - Single-Stage - R-410A Refrigerant (Scratch & Dent)
Goodman GSZ140301-SD
Loading
Goodman GSZ140301-SD
Goodman GSZ140301-SD
×
Customer Review Images
Loading
Scroll Up ArrowTo Top