New NewThis product is new and has never been used. It's in its original packaging, which has not been opened.
Weight
90 Pounds 90 PoundsTotal weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
Type
Gas Furnace
Product Line
GMES80
View More
Orientation
OrientationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Cabinet Width (Inches)
+Share This Product
Recommended Accessories
Required AccessoriesAdd All Required
Installation Accessories
Features
Features
Overview for Goodman GMES800603AX
Goodman's GMES80 furnaces feature high-quality construction and efficient operation at a great value. The GMES80 single-stage, multi-speed furnaces utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. Instead of a standard multi-speed blower motor, the GMES80 utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GMES80 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GMES80.
Multi-speed ECM blower motor with continuous fan speed
Silicon Nitride igniter
Fault code LED Output
AHRI Certified and ETL Listed
Single-stage gas valve
Self-diagnostic control board
Our SKU number(s): Goodman GMES800603AX
The manufacturer model number(s): Goodman GMES800603AX
Specifications
Specifications
General Information
Type
Gas Furnace
Product Line
GMES80
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Single Stage
Blower Motor
ECM Multi-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
UPC
663051591257
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
80 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
48000 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx.
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
8.7 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
14 Inches
Product Height
33 1/2 Inches
Product Width
14 Inches
Product Depth
28 Inches
Product Weight
90 Pounds
Shipping Weight
100 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
203401026
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Heat Exchanger Warranty
Lifetime Years
Reviews
Reviews
Do You Own This Product?
Give us your opinion on this product and help any future buyer's make an informed decision.
+Thank You For Submitting Your QuestionYour submission has been sent successfully. Please give our product specialists up to two business days to respond.