Williamson 161K BTU 91.0% AFUE Hot Water Gas Boiler Direct Vent

Model: GWC-175-N-T-S2 Item Number: 31058
Williamson-Thermoflo GWC-175-N-T-S2
PREVIOUS
NEXT
Williamson-Thermoflo GWC-175-N-T-S2
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    464 Pounds Learn More
    464 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Line
    GWC
    Medium
    Hot Water
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Williamson-Thermoflo GWC-175-N-T-S2

"Uncover warm possibilities" with Williamson-Thermoflo's GWC Gas Water Condensing boiler. The highly efficient GWC-175-N-T-S2 pumps out 175,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 91.0 percent. Not only is the GWC efficient, but it is also versatile with several PVC or stainless steel venting options that can be used. This factory-packaged boiler has many features; like a multiple pass heat exchanger with a secondary stainless steel condensing heat exchanger, control module with indicator lights, hot surface ignition system, and an insulated heavy-gauge steel jacket. The GWC also has an inferred heat program that provides automatic adjustment of the water temperature to match the needs for your residence or office. It is also factory tested, meaning that you can rest assured knowing that you will receive a boiler that you can count on, year after warm year.
  • High Efficiency
  • With an AFUE percentage at or above 91 percent there is no doubt that the boiler will provide you with high efficiency, saving you money on heating costs.
  • Factory Tested
  • GWC boilers are factory tested, ensuring reliability and properly functioning equipment.
  • Secondary Heat Exchanger
  • A stainless steel heat exchanger collects heat from the flue gasses, maintaining boiler efficiency.
  • Inferred Heat Program
  • GWC is designed with an inferred heat program which provides automatic adjustment of the boiler water temperature to match heating demands.
  • Multiple Venting Options
  • Multiple venting setups for both PVC or stainless steel provide you with many options for venting your boiler.
  • Product Includes
  • Taco 007 Circulator Pump
  • Specifications
    View More

    Specifications

    General Information
    Product Line
    GWC
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Condensing
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    No
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Mount Type
    Floor
    Minimum Altitude
    0 Feet
    Maximum Altitude
    5500 Feet
    Assembly Type
    Packaged
    Includes Pump
    Yes
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    91 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    175000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    161000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    140000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    3 Inches
    Gas Connection Size
    1/2 Inch
    Supply Connection
    1 Inch
    Return Connection
    1 Inch
    Product Height
    30 3/4 Inches
    Product Width
    24 5/8 Inches
    Product Depth
    37 3/4 Inches
    Product Weight
    464 Pounds
    Shipping Weight
    474 Pounds
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    2 Years
    Heat Exchanger Warranty
    20 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Williamson 161K BTU 91.0% AFUE Hot Water Gas Boiler Direct Vent
    Williamson-Thermoflo GWC-175-N-T-S2
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top