Weil-McLain 44K BTU 84.0% AFUE Hot Water Propane Boiler Chimney Vent

Model: CGa-25-PIDL Item Number: 49385
Weil-McLain CGa-25-PIDL
PREVIOUS
NEXT
Weil-McLain CGa-25-PIDL
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Try This Instead
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    200 Pounds Learn More
    200 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Line
    CGa
    Medium
    Hot Water
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Weil-McLain CGa-25-PIDL

Overview for Weil-McLain 381357828Over the last 130 years, Weil-McLain has built a reputation of designing some of the most reliable boilers in the marketplace. Their dedication to producing lasting heating solutions is seen in every boiler they make. The CGa is a compact, natural draft boiler. The low profile makes this boiler perfect for space conscious applications with chimney access. Solid construction and a good efficiency rating make the CGa an excellent value. A vent damper, draft hood, and Taco circulator are included. These components, coupled with easily accessible controls, make it easy to install and set your CGa up. Whether you are replacing an older boiler or beginning new construction, the CGa is an efficient, compact heating solution.
Product Features
Efficiency-Boosting InsulationHeat retention is critical to energy efficiency. Heat leakage represents energy use without any comfort gains. An extended, insulated steel jacket prevents heat from escaping the CGa and improves the efficiency.Durable ConstructionReliability is one of the greatest ways a boiler can provide value. Weil-McLain wanted to be sure that you'll enjoy the comfort the CGa provides for years to come. With a steel base and burners and cast-iron boiler sections, they have done just that.
Product Includes
  • (1) Weil-McLain CGa-25-PIDL Hot Water Boiler
  • (1) Taco 007 Circulator
  • (1) Vent Damper
  • (1) Draft Hood
  • Efficiency-Boosting Insulation
  • Heat retention is critical to energy efficiency. Heat leakage represents energy use without any comfort gains. An extended, insulated steel jacket prevents heat from escaping the CGa and improves the efficiency.
  • Durable Construction
  • Reliability is one of the greatest ways a boiler can provide value. Weil-McLain wanted to be sure that you'll enjoy the comfort the CGa provides for years to come. With a steel base and burners and cast-iron boiler sections, they have done just that.
  • Specifications
    View More

    Specifications

    General Information
    Product Line
    CGa
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Liquid Propane
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Conventional
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Chimney Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    No
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Mount Type
    Floor
    Minimum Altitude
    0 Feet
    Maximum Altitude
    4500 Feet
    Includes Pump
    Yes
    Assembly Type
    Packaged
    Gas Conversion Kit
    Available
    UPC
    0672619193765
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    84 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    52000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    44000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    38000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    4 Inches
    Gas Connection Size
    1/2 Inch
    Supply Connection
    3/4 Inch
    Return Connection
    3/4 Inch
    Product Height
    28 3/8 Inches
    Product Width
    10 Inches
    Product Depth
    23 1/4 Inches
    Product Weight
    200 Pounds
    Shipping Width
    27 1/2 Inches
    Shipping Height
    31 1/2 Inches
    Shipping Depth
    27 Inches
    Shipping Weight
    200 Pounds
    Certifications
    Country of Origin
    United States
    CSA Listed
    Yes
    ASME Certified
    Yes
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    2 Years
    Heat Exchanger Warranty
    20 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Weil-McLain 44K BTU 84.0% AFUE Hot Water Propane Boiler Chimney Vent
    Weil-McLain CGa-25-PIDL
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top