Crown Boiler Cayman - 201K BTU - 83.2% AFUE - Hot Water Propane Boiler - Chimney Vent - Includes DHW Coil

Model: CWI241ELTT1PSU Item Number: 24087
Crown Boiler Co. CWI241ELTT1PSU
PREVIOUS
NEXT
Crown Boiler Co. CWI241ELTT1PSU
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Weight
    382 Pounds Learn More
    382 Pounds
    Total weight of the product and any included accessory/components. This total is not the shipping weight, as it does not include packing material, which may increase the overall shipping weight of this product.
    Product Line
    Cayman
    Medium
    Hot Water
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Crown Boiler Co. CWI241ELTT1PSU

Crown's Cayman line of boilers is designed to be an all-encompassing heating solution for home ranging in size from a small condo to a full multi-bedroom household. The heat exchanger at its core is constructed of cast-iron, a material proven effective in hundreds of heating applications around the world. The footprint of the Cayman is smaller than average making it perfect for compact utility rooms, and it comes with a low-clearance vent opening to maximize venting flexibility and installation options. The key feature of the Cayman line is the included tankless water heater coil, an internal accessory that allows the boiler to provide domestic hot water for showers and kitchen needs while heating the air in your home at the same time.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Cayman is made of durable cast iron, a material proven many times over for its reliability in heating applications and efficiency in heat transfer.
  • Built-In Tankless Coil
  • The Crown Cayman boilers come with a built-in tankless water heater coil, allowing the boiler to handle all of your domestic hot water needs without an external hot water tank. This also means that your home has an endless supply of hot water.
  • Low Clearance Draft Diverter
  • Crown's Cayman line of boilers come with a very low height draft diverter, allowing it to be installed in low height areas or in areas with complicated venting configurations.
  • Included Automatic Vent Damper
  • An automatic vent damper is included with the Cayman boilers. It regulates the exhaust gas flow from your boilers venting system, allowing more heat to be kept inside the boiler for increased efficiency.
  • Specifications
    View More

    Specifications

    General Information
    Product Line
    Cayman
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Liquid Propane
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Conventional
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Chimney Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    Yes
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Mount Type
    Floor
    Minimum Altitude
    0 Feet
    Maximum Altitude
    2000 Feet
    Includes Pump
    Yes
    Assembly Type
    Packaged
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    83.2 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    241000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    201000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    175000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    120 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    7 Inches
    Supply Connection
    1 1/4 Inches
    Return Connection
    1 1/4 Inches
    Product Height
    40 7/16 Inches
    Product Width
    29 Inches
    Product Depth
    30 Inches
    Product Weight
    382 Pounds
    Certifications
    Country of Origin
    United States
    ETL Listed
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    2100223
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    20 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Crown Boiler Cayman - 201K BTU - 83.2% AFUE - Hot Water Propane Boiler - Chimney Vent - Includes DHW Coil
    Crown Boiler Co. CWI241ELTT1PSU
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top