Crown Boiler Bali - 134K BTU - 82.5% AFUE - Hot Water Propane Boiler - Direct Vent

Model: BWF162ELST2PSU Item Number: 24020
Crown Boiler Co. BWF162ELST2PSU
PREVIOUS
NEXT
Crown Boiler Co. BWF162ELST2PSU
Enlarge Image
Product Discontinued
Sorry, this product is no longer available.
Specification Highlights
    Condition
    New Learn More
    New
    This product is new and has never been used. It's in its original packaging, which has not been opened.
    Product Line
    Bali
    Medium
    Hot Water
    Heat Exchanger Material
    Cast Iron
Recommended Accessories
View More
Required Accessories Add All Required
Installation Accessories
Features
View More

Features

Overview for Crown Boiler Co. BWF162ELST2PSU

Crown's Bali line of boilers was designed specifically for the house without a chimney, or for homes where the chimney is unusable for venting purposes. It features a built in exhaust fan, making it ideal for sidewall venting applications or other arrangements where flue exhaust needs to travel a long horizontal distance. Its heat exchanger is made from durable cast iron and has been proven reliable in thousands of home installations. Fiberglass insulation and an integrated boiler control make the Bali a complete, full featured home heating solution.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Bali is made of durable cast iron, a material proven many times over for its reliability in heating applications and efficiency in heat transfer.
  • Power Venting System
  • The Crown Bali boilers are designed for homes without a chimney or where the chimney cannot be used for venting. An exhaust fan is built into the boiler, which makes it perfect for side-wall venting arrangements.
  • Fiberglass Insulation
  • The jacket of Bali boilers is lined with a thick layer of high-grade fiberglass insulation, keeping as much heat as possible inside the boiler. This means more heat to your home for less!
  • Integrated Boiler Control
  • This boiler comes with a control which features temperature control functionality, ignition functions, and a second circulator output for controlling an additional heating zone or flow to an indirect fired water heater.
  • Specifications
    View More

    Specifications

    General Information
    Product Line
    Bali
    Medium Learn More
    Medium
    Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
    Hot Water
    Heat Exchanger Material
    Cast Iron
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Liquid Propane
    Combustion Type Learn More
    Combustion Type
    Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
    Conventional
    Vent Type Learn More
    Vent Type
    Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
    Direct Vent
    DHW Production Learn More
    DHW Production
    DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
    No
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
    Single Stage
    Mount Type
    Floor
    Minimum Altitude
    0 Feet
    Maximum Altitude
    2000 Feet
    Assembly Type
    Packaged
    Includes Pump
    Yes
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace.
    82.5 %
    Maximum Input Capacity Learn More
    Maximum Input Capacity
    The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
    162000 BTU
    DOE Heating Capacity Learn More
    DOE Heating Capacity
    Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
    134000 BTU
    Net I=B=R Capacity Learn More
    Net I=B=R Capacity
    I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
    117000 BTU
    Ultra Low NOx Emissions Learn More
    Ultra Low NOx Emissions
    NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx.
    No
    Electrical Data
    Voltage
    120 Volts
    Phase
    1
    Frequency
    60 Hz
    Dimensions
    Flue Connection Size
    3 Inches
    Supply Connection
    1 1/4 Inches
    Return Connection
    1 1/4 Inches
    Product Height
    35 11/16 Inches
    Product Width
    24 Inches
    Product Depth
    26 3/4 Inches
    Shipping Weight
    432 Pounds
    Certifications
    Country of Origin
    United States
    ETL Listed
    Yes
    AHRI Certified
    Yes
    AHRI Reference Number
    2100293
    Warranty Information
    Parts Warranty Show ACW Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    1 Year
    Heat Exchanger Warranty
    20 Years
    Reviews
    View More

    Reviews

    Do You Own This Product?

    Give us your opinion on this product and help any future buyer's make an informed decision.

    Manuals
    View More
    Share
    ×
    Crown Boiler Bali - 134K BTU - 82.5% AFUE - Hot Water Propane Boiler - Direct Vent
    Crown Boiler Co. BWF162ELST2PSU
    Loading
    ×
    Customer Review Images
    Loading
    Scroll Up ArrowTo Top